• Excellent Vibration Resistance Working Pressure 4.0MPa DN1600 O2 Coal Gas Steam Plug-in Vortex Flowmeter
  • Excellent Vibration Resistance Working Pressure 4.0MPa DN1600 O2 Coal Gas Steam Plug-in Vortex Flowmeter
  • Excellent Vibration Resistance Working Pressure 4.0MPa DN1600 O2 Coal Gas Steam Plug-in Vortex Flowmeter
  • Excellent Vibration Resistance Working Pressure 4.0MPa DN1600 O2 Coal Gas Steam Plug-in Vortex Flowmeter
  • Excellent Vibration Resistance Working Pressure 4.0MPa DN1600 O2 Coal Gas Steam Plug-in Vortex Flowmeter
  • Excellent Vibration Resistance Working Pressure 4.0MPa DN1600 O2 Coal Gas Steam Plug-in Vortex Flowmeter

Excellent Vibration Resistance Working Pressure 4.0MPa DN1600 O2 Coal Gas Steam Plug-in Vortex Flowmeter

After-sales Service: One Year Warranty
Warranty: Life-Long Maintenance
Accuracy: 0.5%-2.5%F.S
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Size: DN15-DN1600
Sensor: Tube/Flange
Samples:
US$ 325/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Company Profile
  • Packaging & Shipping
  • FAQ
  • More recommendation
Overview

Basic Info.

Model NO.
QLJ602
Application
Industrial Production
Type
Vortex Flow Meter
Measuring Media
Gas, Liquid, Steam
Measuring Principle
Hydrodynamics
Measurement Object
Closed Pipeline
Certification
CE
Norminal Pressure
1.6MPa ~4.0MPa
Range Degree
1:10
Converter Power Supply
Voltage Pulse Output:+12VDC;
Output Signal
Voltage Pulse/4-20mA Current Output/Hart Agreement
Ambient Temperature
Voltage Pulse Output:-30°ºC~+65
Protection Grade
Ordinary Type: IP65
Transport Package
Carton
Specification
0.5kg
Trademark
XYT Meter
Origin
China
HS Code
902610000
Production Capacity
50000 Piece /Years

Product Description

Product Description
Overview
The QLJ602 Intelligent Vortex flowmeter is a kind of velocity flowmeter.Based on Karman vortex theory, it uses piezoelectric crystal to detect the vortex frequency generated by the fluid passing through the triangular column in the pipeline, so as to measure the flow rate of the fluid.
It has features of not only excellent anti-vibration performance, zero drift , high reliability,but not contact with the medium and so on, which is widely used in the measurement and control of steam, gas and liquid flow in petroleum, chemical, metallurgy, heat, textile, paper and other industries.
Features

`Excellent vibration resistance, zero drift and high reliability.
`The detection element is not in contact with the medium, stable performance and long service life.
`Wide measuring range, maximum range ratio up to 20:1, vortex flowmeter measurement volume flow without compensation,
`In a certain range of Reynolds number, the flow characteristics are not affected by the fluid pressure, temperature, viscosity, density and composition, but only by the shape and size of the vortex-generating body.
`Wide range of applications, can measure steam, gas, liquid flow
`Simple structure, firm, no moving parts, easy operation and maintenance.
`The surface body is made of stainless steel and corrosion-resistant.
Excellent Vibration Resistance Working Pressure 4.0MPa DN1600 O2 Coal Gas Steam Plug-in Vortex Flowmeter

Technical Parameters
Norminal Diameter DN15~DN1600(Flange connection
type:DN15~DN300; plug-in type: 300~1000 )
Medium temperature Piezoelectric type:-20ºC~150ºC;
Capacitance:-20ºC~250ºC,-20ºC~350ºC;
Norminal pressure 1.6MPa ~4.0MPa (Special pressure can be customized)
Accuracy level Liquid:±0.5%F.S,
Gas,steam:±1.0%F.S,
Plug-in:±2.5%F.S
Range degree 1:10
Medium velocity range Liquid:0.6~6m/s;
Gas:5~60m/s;
Steam:5~70m/s
Environment  condition
 
Ambient temperature:-20ºC~55ºC;
Relative humidity :5%~90%;
Atm pressure: 86~106kPa

Converter power supply
Voltage pulse output:+12VDC;
4~20mA Current output:+24VDC;
Live LCD display:3.6V1 No.1 lithium battery power supply, the service life is more than 2 years
Output Signal Voltage pulse/4-20mA Current output/HART Agreement/RS485.
Ambient temperature Voltage pulse output:-30°ºC~+65°ºC;
4~20mA Current output:-10°C~+55°C;
Live LCD display:-25°C~+55°C
Loss coefficient JB/T9249 Cd≤2.4
Anti-explosion condition
 
Intrinsic safety type:ExdIIia CT2-T5 Anti-explosion type:ExdIICT2-T5

Protection grade
Ordinary type: IP65
Dive type: IP68


Types
Stucture type: Split type,Integral type
Connection mode: Flange connection type, clamp connection type,thread connection type, plug-in type
Function type: with temperature compensation or not

Transmission range
 
three-wire system flow sensor:≤300m,electric sign of two-wire system transmitter (4~20mA):load
resistance≤750Ω
Body material 1Cr 18Ni 9Ti (0ther materials according agreement to supply)


Application
Gases (air, oxygen, nitrogen, gas, natural gas,chemical gas, etc.), liquids (water,high temperature water, oil, food liquid, chemical liquid, etc.),steam
(saturated steam, superheatedsteam)

Dimension
Excellent Vibration Resistance Working Pressure 4.0MPa DN1600 O2 Coal Gas Steam Plug-in Vortex Flowmeter
Other model
Excellent Vibration Resistance Working Pressure 4.0MPa DN1600 O2 Coal Gas Steam Plug-in Vortex Flowmeter
Excellent Vibration Resistance Working Pressure 4.0MPa DN1600 O2 Coal Gas Steam Plug-in Vortex Flowmeter
Excellent Vibration Resistance Working Pressure 4.0MPa DN1600 O2 Coal Gas Steam Plug-in Vortex Flowmeter
                      Clamp-on type                                              Thread type                                          Plug-in type
Excellent Vibration Resistance Working Pressure 4.0MPa DN1600 O2 Coal Gas Steam Plug-in Vortex Flowmeter
Excellent Vibration Resistance Working Pressure 4.0MPa DN1600 O2 Coal Gas Steam Plug-in Vortex Flowmeter
                                    Split type                                                          Temperature and pressure compensation type

 
Company Profile

Excellent Vibration Resistance Working Pressure 4.0MPa DN1600 O2 Coal Gas Steam Plug-in Vortex FlowmeterExcellent Vibration Resistance Working Pressure 4.0MPa DN1600 O2 Coal Gas Steam Plug-in Vortex FlowmeterExcellent Vibration Resistance Working Pressure 4.0MPa DN1600 O2 Coal Gas Steam Plug-in Vortex Flowmeter

 
Packaging & Shipping

Excellent Vibration Resistance Working Pressure 4.0MPa DN1600 O2 Coal Gas Steam Plug-in Vortex Flowmeter
FAQ

1. How long will you reply to me?
Normally in 1 hours, no more than 12 hours.
2. How can I get the quotation?
Please provide specification and application including sensing element, pressure range, thread connection, pressure type, medium, electronic connection, shell material etc. More details, more accurate quotation and earlier response.
3. Can I get sample?
Contact with our staff online directly and they would check stock for you.
4. Can I visit your factory?
You are warmly welcomed, our factory is located at Baoji city, Shaanxi province, China.
5. Can we use our logo on the products?
Yes, we provide OEM/ODM service.
6. How long is your warranty period?
Warranty period from the date of acceptance of 12 months.
7. What is your terms of payment?
We could accept T/T, L/C, Western union, PayPal, credit Assurance.
More recommendation

Excellent Vibration Resistance Working Pressure 4.0MPa DN1600 O2 Coal Gas Steam Plug-in Vortex Flowmeter

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now