• 15~24VDC 4-20mA Two Three Wire Vortex Flowmeter
  • 15~24VDC 4-20mA Two Three Wire Vortex Flowmeter
  • 15~24VDC 4-20mA Two Three Wire Vortex Flowmeter
  • 15~24VDC 4-20mA Two Three Wire Vortex Flowmeter
  • 15~24VDC 4-20mA Two Three Wire Vortex Flowmeter
  • 15~24VDC 4-20mA Two Three Wire Vortex Flowmeter

15~24VDC 4-20mA Two Three Wire Vortex Flowmeter

After-sales Service: 3 Years
Warranty: 3 Years
Accuracy: ≤±0.1%
Main Application: Water, Corrosive Liquid/Gas
Size: DN15-300
Sensor: Plug-in
Samples:
US$ 190/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
Vortex flowmeter
Application
Environmental Protection
Type
Vortex Flow Meter
Measuring Media
Gas, Steam, Liquid
Measuring Principle
Electrical Principles
Measurement Object
Open Channel
Certification
CE, ISO
Applicable Caliber
DN15-300, Other Caliber to Contact Suppliers
Applicable Medium
Gas, Steam, Liquid
Ambient Temperature
(-30~+70)ºC
Ambient Temperature for LCD Display
(-20~+ 60)ºC
Relative Humidity
5%~90%
Atmospheric Pressure
(80~106) Kpa. 3.Power Supply:
Transport Package
Carton
Specification
2kg
Trademark
XYT Meter
Origin
China
HS Code
9026100000
Production Capacity
3000PCS/Month

Product Description


15~24VDC 4-20mA Two Three Wire Vortex Flowmeter
 
Product Description

VT2/3WE:Two/Three -wire Vortex flowmeter
VT2WE: Two-wire Vortex flowmeter
VT33WE: Three-wire Vortex flowmeter
Qt: accumulated measurement value
Qn: real time measured value or instantaneous value
Qi:output current

Main technical parameters

1.Applicable caliber: Dn15-300, other caliber to contact suppliers.
Applicable medium: gas, steam, liquid.
2. Environmental conditions
ambient temperature: (-30~+70)ºC
ambient temperature for Lcd display:(-20~+ 60)ºC
relative humidity: 5%~90%
atmospheric pressure: (80~106) kPa.
3.Power supply:
A) VT3WE
(1) external power supply: 12~24VDC/30mA
(2) battery: 3.6V disposable lithium battery.
B) VT2WE
 15~24VDC/ 4-20mA 
4.the output signal and communication
A) VT3WE
(1) Pulse output: high level ≥10V (supply voltage -1v), low level < 0.5v.
(2) NPN Open collector output with 2K pull-up resistance.
(3)ModBus485-RTU communication: the meter communicate according ModBus485-RTU protocol specification. communication distance ≤ 1200mm.
 B) VT2WE
(1) 4 ~ 20mA linear correction current output, circuit load < 500 Ω.
(2) without correction output of the original pulse with light isolation, high level ≥10V (supply voltage -1v),low level < 0.5v; NPN Open collector output with 2K pull-up resistance. An additional 12V power supply is required.
15~24VDC 4-20mA Two Three Wire Vortex Flowmeter
15~24VDC 4-20mA Two Three Wire Vortex Flowmeter
15~24VDC 4-20mA Two Three Wire Vortex Flowmeter
15~24VDC 4-20mA Two Three Wire Vortex Flowmeter
15~24VDC 4-20mA Two Three Wire Vortex Flowmeter
15~24VDC 4-20mA Two Three Wire Vortex Flowmeter

Basic overview
VT2/3WE serial Vortex flowmeter integrated with 16-bit MCU processor, and the amplifying circuit is of analog type. The flow rates of gas, liquid and steam can be accurately measured within a conventional flow range. Can be set by the dial switch to adapt to various caliber and all kinds of measuring media. VT3WEC system communicate according ModBus485-RTU protocol specification, and can use battery power. VT2WE system output 4-20mA current and isolated original Pulse.

Wire connection
the terminal blocks is on the amplifier board. The large terminal is the required main terminal and the small terminal is the auxiliary terminal for additional function wiring.
 

Wire connection of VT3WE

Main power supply and output signal terminal
GND Fout   V +
"GND": is the "-" end of the power supply.    
"Fout": is the pulse output terminal.     
"V+" : is the "+" terminal of external 12V~24VDC power supply.
Note:
When V+ and GND are connected to an external power source, the circuit works (the battery-powered model is transferred to an electrician), and the pulse output is drawn from Fout.
Auxiliary wiring (small terminal) the double-pin jumper wire between the main terminal and the auxiliary terminal is the battery switch. When  it is short connected battery is on; battery is off, When it is disconnected.

Battery and communication terminal
+ 3 V6 3 V6 - CMB- CMA+
1) battery terminal(1,2 bit right of small terminal)
"+3V6": connect to the "+" end of 3.6V lithium battery.     
"3V6-" : connect to the "-" end of 3.6V lithium battery
2) communication terminal (3,4 bit left of small terminals)
"CMB-": connect the "-" or "B" end of RS485 wires.
"CMA+": connect the "+" or "A" end of RS485 wires.


Wire connection of VT2WE
1. Main power supply and current output terminal
    -    +
"-" : is the output terminal of 4~20mA current. and also is the "-" end of 15-24v power supply    
"+" : is the "+" end of 15-24v power supply
The ammeter or sampling resistance is between the "-" end and the negative of power.
Auxiliary terminal (3 small terminals)
V + Fout GND
"V+" : connect to the positive of the power supply (+12V).
"Fout": is the pulse output signal terminal.
"GND": connect to the negative of the power supply.
This pulse output must be used in the case of power supply in the main current loop. The output is the uncorrected original pulse with 50Hz excised with light isolation, which is usually used in calibration. The output signal is NPN open collector output with 2K pull-up resistance.
Company Profile

FQA

1. How long will you reply to me?
Normally in 1 hours, no more than 12 hours.
2. How can I get the quotation?
Please provide specification and application including sensing element, pressure range, thread connection, pressure type, medium, electronic connection, shell material etc. More details, more accurate quotation and earlier response.
3. Can I get sample?
Contact with our staff online directly and they would check stock for you.
4. Can I visit your factory?
You are warmly welcomed, our factory is located at Baoji city, Shaanxi province, China.
5. Can we use our logo on the products?
Yes, we provide OEM/ODM service.
6. How long is your warranty period?
Warranty period from the date of acceptance of 12 months.
7. What is your terms of payment?
We could accept T/T, L/C, Western union, PayPal, credit Assurance.