Type: Wall-Mounted Current Type
Measuring Medium: Temperature
Display Type: No Display
Site Display: Not Site Display
Accuracy: 0.5
IP Rating: IP65
Samples:
US$ 6.5/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Certification
ISO
Customized
Customized
Input Signal
Thermal Resistance (Rtd), Thermocouple (Tc)
Supply Voltage
DC12-40V
Stored Temperature
-40-100ºC
Output Signal
4-20mA
Transport Package
Carton
Specification
0.15kgs
Origin
China
Production Capacity
500000

Product Description

Overview
The intelligent temperature transmitter (round card) is used for the input of thermal resistance (RTD) and thermocouple (TC) signals and the output of 2-wire 4-20ma analog system. It is installed inside the sensor (Form B).
Specification
Enter
input signal Thermal resistance (RTD), thermocouple (TC)
Cold junction compensation range -20~60ºC
Compensation accuracy ±1 ºC
Output
output signal 4~20mA
Load Resistance RL≤(Ue-12)/0.021
Upper and Lower limit overflow
alarm output current
IH=21mA,IL=3.8mA
Power supply
Supply voltage DC12~40V
Other parameters
Temperature drift 0.02%FS/ºC
Response time 1s reaches 90% of final value
Working temperature -40~80ºC
Stored temperature -40~100ºC
Shock resistance 4g/2~150Hz
installation angle Unlimited
Installation area b-type top box mounting
Electromagnetic Meet the requirements of gb / t18268 industrial equipment

Input type and transmission accuracy
el Types Measuring Minimum Measuring Conversion Note:
1.The above accuracy data is obtained by testing under the environment temperature of 20 ºC
± 2 ºC.


2.The output accuracy "%" is relative to the set range. 3.The cold junction compensation error needs to be added when measuring the thermocouple




















 

RTD
Pt100 -200.0~850.0ºC 10ºC ≤100ºC 0.2%
>100ºC 0.1%
Cu50 -50.0~150.0ºC 10ºC ≤100ºC 0.2%
>100ºC 0.1%









TC
B 400~1800ºC 500ºC ≤300ºC 0.2%
>300ºC 0.1%
E -100~1000ºC 50ºC ≤300ºC 0.2%
>300ºC 0.1%
J -100~1200ºC 50ºC ≤300ºC 0.2%
>300ºC 0.1%
K -180~1372ºC 50ºC ≤300ºC 0.2%
>300ºC 0.1%
N -180~1300ºC 50ºC ≤500ºC 0.2%
>500ºC 0.1%
R -50~1768ºC 500ºC ≤500ºC 0.2%
>500ºC 0.1%
S -50~1768ºC 500ºC ≤500ºC 0.2%
>500ºC 0.1%
T -200~400ºC 50ºC ≤500ºC 0.2%
>500ºC 0.1%
Wre3-25 0~2315ºC 500ºC ≤500ºC 0.2%
>500ºC 0.1%
Wre5-26 0~2310ºC 500ºC ≤500ºC 0.2%
>500ºC 0.1%


Smart PT100 to 4-20mA Head Mounted Temperature Transmitter
Smart PT100 to 4-20mA Head Mounted Temperature TransmitterSmart PT100 to 4-20mA Head Mounted Temperature TransmitterSmart PT100 to 4-20mA Head Mounted Temperature TransmitterSmart PT100 to 4-20mA Head Mounted Temperature TransmitterSmart PT100 to 4-20mA Head Mounted Temperature TransmitterSmart PT100 to 4-20mA Head Mounted Temperature Transmitter



 