Good Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine Flowmeter

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Still deciding? Get samples of US$ 25/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001
OEM/ODM Availability
Yes
  • Good Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine Flowmeter
  • Good Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine Flowmeter
  • Good Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine Flowmeter
  • Good Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine Flowmeter
  • Good Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine Flowmeter
  • Good Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine Flowmeter
Find Similar Products

Basic Info.

Model NO.
QLK401
Accuracy
1%
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil
Size
1", 2", 3"
Sensor
Tube/Flange
Application
Industrial Production
Type
Turbine Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Open Channel
Certification
CE, ISO
Application Medium
Diesel, Light Oil
Unit Count
5 Digits
Flow Rate
20-150 Lpm
Material
Aluminum/ Stainless Steel
Battery
AAA Battery
Output
RS485
Connection Method
Threaded Connection
Transport Package
Carton
Specification
45X43X20 Cm
Trademark
XYT
Origin
China
HS Code
9026201090
Production Capacity
5000/Month

Product Description

Good Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine FlowmeterOverview
Electronic Aluminum Turbine Pulser Digital Diesel Fuel Flow Meter with LCD Display
With high accuracy, durable life, small volume, Electronic Aluminum Turbine Pulser Digital Diesel Fuel Flow Meter Series are mainly used to transfer light oil such as diesel, gasoline. Its module design can be used with output module, sensor and long-distance transfers. Other Material like Plastic or Stainless Steel are also available.

The model designed can be used in conjunction with output module, sensor and remote transmitter.
Good repeatability and strong stability, unique LCD (LCD)count, you can reset the 5 bit (9999.9) single oil volume, a cumulative total of 6 bits are not cleared. The accuracy ofthe positive and the negative is less than or equal to 1%the repeatability error of less than 2% units of measurement for (/L, /GAL /QTS a gallon, quart, pint (PTS)switch freely is the rise in domestic basic, easy to use), two keys (CALIBRATE DISPLAY) with the use of simple and easy to operate!

 
Model Number Item Data
Inlet Size 1' 1.5'
Flow Rate 20-150 lpm 40-350 lpm
Body Material Aluminum Aluminum
Application Medium Diesel, light oil Diesel, light oil
Unit Count 5 digits 5 digits
Total Count 5 digits Accumulationx100 999,990
Max.Working Pressure 290pa(20 bar) 290pa(20 bar)
Package 20 pcs/carton 20 pcs/carton
Carton Dimension 45x43x20 cm 45x43x20 cm
G.W/N.W 12kgs/11kgs 15kgs/14kgs
SELECTIONS FOR MRC-FM-WL100
Model MRC-FM-WL100
Material Aluminium
Stainless steel
Size 1", 1.5", 2", 2.5", 3"
Good Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine FlowmeterGood Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine FlowmeterGood Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine FlowmeterGood Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine FlowmeterGood Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine FlowmeterGood Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine FlowmeterGood Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine FlowmeterGood Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine FlowmeterSet of Measurment Unit
Under the state of standby or current charging display, press the button of CAL and RESET at the same time for 5 seconds. Enter the setting of unit conversion and press the RESET button, choose the measurement unit in turn according to the order of LTR→GAL→PT→QT→LTR, meanwhile the accumulated charging quantity will be displayed based on the conversion of the current measurement unit conversion. Then press the CAL button for 3 seconds to quit the unit conversion setting.

Error Coefficient Calibration
Under the state of standby or current charging display, press the button of CAL for 3 seconds, entering the state of error
coefficient calibration. Meanwhile when the first digital blinking displays, press the MENU button, then numeric shift (blinking digital displacement), press the RESET button, modify the current blinking figure, from 0 to 9 in turn, then back to 0. The oil pump capacity is less when the digital is increased; vice versa. Press the button CAL for 3 seconds to quit the error coefficient calibration. Back to the state of current charging quantity, and display it as reset. After the error coefficient calibration, demarcate it when there is new measuring pulse input. The range of the error coefficient calibration is from 0.1000 to 9.9999. Press the button of CAL and RESET at the same time to check the coefficient and total accumulated figure.


Example of Error Coefficient Adjustment
When the original figure is 1.000, it will display as 100 L oil, the actual oil pump capacity is also 100 L. In case the user
wants to reduce 2 L oil, then press the button of CAL for 3 seconds, adjust it to 1.020 according to the Error coefficient
Calibration. Then the oil pump capacity will be 98 L. For 96 L, adjust it to 1.040; visa versa.
Battery Low Prompt
When the voltage of battery is between 2.2 v to 2.4 v, it will display as LBAT, to remind the user to replace the battery.


Maintenance and Preservation
This flow meter needs the battery with life span of at least 9,000 hours (1 year) as the power supply. The short battery life will lead to the battery leakage during working and result in the damage of the flow meter. The standby life of this flow meter is designed as 2 years. Battery replacement every one year is recommended. In case the LCD display becomes dim or the LBAT occurs, it is time to replace the battery. We recommend the users to check the Battery electrode to clear the rusting in case. Take out the battery if the flow meter is not used for a long time.
Good Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine FlowmeterGood Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine FlowmeterGood Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine Flowmeter
Good Price 1" 2" Digital LCD Display Diesel Electronic Small Turbine Flowmeter
FAQ
1. How long will you reply to me?
We will reply to you as soon as possible. Normally in 1 hours, no more than 12 hours.
2. How can I get the quotation?
Please provide the site conditions and product requirements. The selection table is provided for your reference. Please let me know the quantity you need. The more quantity, the greater the discount.
3. Can I get a sample?
Contact our staff online directly and they will check stock for you.
4. Can I visit your factory?
You are warmly welcomed, our factory is located in Baoji City, Shaanxi Province, China.
5. Can we use our logo on the products?
Yes, we provide OEM/ODM service.
6. How long is your warranty period?
The warranty period from the date of acceptance of 12 months.
7. What are your terms of payment?
We could accept T/T, L/C, PayPal, and credit Assurance.
8. What's the transport?                                                              
Express such as DHL, Fedex, TNT, UPS for freight prepaid, also can use your own couier account to do the freight collect. For more goods we can arrange by air or by Sea.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier