• High Applicability Spdt Output Max 250º C/Min Pipeline Air Water Oil LED Disaplay Thermal Flow Switches
  • High Applicability Spdt Output Max 250º C/Min Pipeline Air Water Oil LED Disaplay Thermal Flow Switches
  • High Applicability Spdt Output Max 250º C/Min Pipeline Air Water Oil LED Disaplay Thermal Flow Switches
  • High Applicability Spdt Output Max 250º C/Min Pipeline Air Water Oil LED Disaplay Thermal Flow Switches
  • High Applicability Spdt Output Max 250º C/Min Pipeline Air Water Oil LED Disaplay Thermal Flow Switches
  • High Applicability Spdt Output Max 250º C/Min Pipeline Air Water Oil LED Disaplay Thermal Flow Switches

High Applicability Spdt Output Max 250º C/Min Pipeline Air Water Oil LED Disaplay Thermal Flow Switches

Type: Electronic
Number of Switch: Single Control Switch
Structure: Power Built-in Type
Usage: Control Switch
Application: Industrial
Explosion-proof Type: Non Explosion-proof
Samples:
US$ 69/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
QLK400
Contact
Normally Open
Contact Type
Type c Contact
Detection Method
Correlation Type
Brand
Xyt Meter
Certification
CE
Transport Package
Carton
Specification
0.5kg
Trademark
XYT Meter
Origin
China
HS Code
9026201090
Production Capacity
50000 Piece /Years

Product Description

Product Description
High Applicability Spdt Output Max 250º C/Min Pipeline Air Water Oil LED Disaplay Thermal Flow Switches
Overview
Flow switch is a measuring instrument that can monitor the liquid flow in the pipeline in real time by multiple LED disaplayers and provide signal output.
It can monitors following conditions:
Flow speed increasing or reducing, medium exists or not, the
medium is moving or not.
It is suitable for a variety of pipe diameter requirements, which can be used to protect idling pump and monitor the flow rate in the pipeline.

 

Features

1.All stainless-steel case without movable components,maintenance-free
2.Switching point could be connected and set on site
3.LED display shows flow state and on-off state
4.Small pressure loss, compact structure

 

Specification
 

Measuring range 1~150cm/s(water),3~300cm/s(oil)
Supply voltage 24±20%VDC
Current consumption <90mA
Signal output
 
relay(SPDT),PNP
Transistor characteristics Switch voltage: 24±20%VDC;
Switch current: ≤1.2A;

 
The relay characteristics Switch voltage: ≤250VAC/30VDC;
Switch current: ≤3A
The initialization time typical value 8s(2~15s)
Response time typical value 2s(1~15s)
Temperature gradient max250ºC/min
Medium temperature -20~80ºC
Ambient temperature    -10~70ºC
Storage temperature range -20~85 ºC
Pressure rating 10MPa
Probe materials
 
304 stainless steel
Housing material
 
304 stainless steel
 
Protection IP67
 


Dimension
High Applicability Spdt Output Max 250&ordm; C/Min Pipeline Air Water Oil LED Disaplay Thermal Flow SwitchesElectrical definitions

High Applicability Spdt Output Max 250&ordm; C/Min Pipeline Air Water Oil LED Disaplay Thermal Flow SwitchesInstallation
High Applicability Spdt Output Max 250&ordm; C/Min Pipeline Air Water Oil LED Disaplay Thermal Flow Switches

Regulation

After install the products on the pipe, please connect the wire connection according to the electrical definition. Switch on the power, then adjust product after 2 minutes.
High Applicability Spdt Output Max 250&ordm; C/Min Pipeline Air Water Oil LED Disaplay Thermal Flow Switches
As shown in the picture above, screw off the anti-dust screw, then we could see the adjustment point of potentiometer. Standing at the cable entry side, rotate the adjustment point in clockwise, the indicator would lights from left to tight in order, light off conversely.

For different applications, follow the steps below to adjust, If the adjustment effect is not ideal, it can be repeated for several times.
NOTE:When the velocity of fluid flow changes from 15 to 30 seconds, then adjust the potentiometer.


1.Medium flow / reduce the flow rate
   a.Set the minimum flow rate or the standard flow rate lower than the set monitoring flow rate
   b.
Adjust the potentiometer, make the right indicator LED lights
   c.Restore the monitoring flow rate, adjust the potentiometer, make the yellow indicator lights and at least one green indicator lights
2.Media presence / absence
Adjust the potentiometer, when the pipeline medium does not flow, make the red indicator lights, when the medium flows, make yellow and at least one green indicator lights.
3.Medium flow / still
Adjust the potentiometer, when there is no medium in the pipeline, make the red indicator light on, when there is a medium in the pipeline or there is a certain flow rate, make the yellow and at least one green indicator light on.
 

 

 
Company Profile

High Applicability Spdt Output Max 250&ordm; C/Min Pipeline Air Water Oil LED Disaplay Thermal Flow Switches

High Applicability Spdt Output Max 250&ordm; C/Min Pipeline Air Water Oil LED Disaplay Thermal Flow Switches
Packaging & Shipping

High Applicability Spdt Output Max 250&ordm; C/Min Pipeline Air Water Oil LED Disaplay Thermal Flow Switches
FAQ

1. How long will you reply me?
Normally in 1 hours, no more than  12 hours.
2. How can I get the quotation?
Please provide specification and application including sensing element, pressure range, thread connection, pressure type, medium, electronic connection, shell material etc. More details, more accurate quotation and earlier response.
3. Can I get sample?
Contact with our staff online directly and they would check stock for you.
4. Can I visit your factory?
You are warmly welcomed, our factory is located at Baoji city, Shaanxi province, China.
5. Can we use our logo on the products?
Yes, we provide OEM/ODM service.
6. How long is your warranty period?
Warranty period from the date of acceptance of 12 months.
7. What is your terms of payment?

We could accept T/T, L/C, Western union, PayPal.
 

Send your message to this supplier