Reliable Accuracy ± 0.15%F. S IP67 Output RS485 Closed Pipeline Coriolis Diesel Oil Air Gas Liquid Mass Flowmeter

Product Details
Customization: Available
Type: Flowmeter
Feature: Intelligent
Still deciding? Get samples of US$ 7330/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001
OEM/ODM Availability
Yes
  • Reliable Accuracy ± 0.15%F. S IP67 Output RS485 Closed Pipeline Coriolis Diesel Oil Air Gas Liquid Mass Flowmeter
  • Reliable Accuracy ± 0.15%F. S IP67 Output RS485 Closed Pipeline Coriolis Diesel Oil Air Gas Liquid Mass Flowmeter
  • Reliable Accuracy ± 0.15%F. S IP67 Output RS485 Closed Pipeline Coriolis Diesel Oil Air Gas Liquid Mass Flowmeter
  • Reliable Accuracy ± 0.15%F. S IP67 Output RS485 Closed Pipeline Coriolis Diesel Oil Air Gas Liquid Mass Flowmeter
  • Reliable Accuracy ± 0.15%F. S IP67 Output RS485 Closed Pipeline Coriolis Diesel Oil Air Gas Liquid Mass Flowmeter
  • Reliable Accuracy ± 0.15%F. S IP67 Output RS485 Closed Pipeline Coriolis Diesel Oil Air Gas Liquid Mass Flowmeter
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
QLJ601
Measuring Medium
Liquid,Gas
Accuracy Grade
0.15%F.S-0.5%F.S
Pressure range
360kg/H~2500000kg/H
IP Rating
IP65
Certification
CE
Customized
Customized
Nominal Diameter
DN3~250
Temperature Accuracy
±1ºC(Repeatabilityj±0.5ºC)
Density Accuracy
±0.001g/cm3(Only Liquid)
Operating Voltage
(85~265)VAC/(12~24)VDC
Output Signal
Output Circulation (4~20)Ma;(0~10)Khzpulseunit
Standard Withstand Voltage
4MPa/25MPa
Medium Temperature
-70ºC~+160ºC
Wetted Parts
AISI316L/Hartz Alloy
Loss of Pressure
≤0.08MPa
Transport Package
Carton
Specification
1kg
Trademark
XYT Meter
Origin
China
HS Code
9026201090
Production Capacity
50000 Piece /Years

Product Description

Product Description
Reliable Accuracy ± 0.15%F. S IP67 Output RS485 Closed Pipeline Coriolis Diesel Oil Air Gas Liquid Mass Flowmeter
Overview
This Mass Flowmeter adopts the latest technology of international mass flowmeter, has a series of advantages such as beautiful appearance, reliable performance and high accuracy, and is welcomed by the majority of users. Mass flowmeter is used to measure the mass flow in the closed pipeline, which is widely used in various fields, especially in chemical industry, electric power, mining and metallurgy, drainage, paper making, medicine, food and other fields.
 

Features
*No moving parts, low maintenance.There are no obstructing parts in the measuring pipe, and the requirements of the straight   pipe section are low
*Wide range of application.The measurement is not affected by fluid density, viscosity, temperature changes
*The flowmeter is ARM system with three calculators: density calculation, temperature calculation and flow calculation,which can   display volume, mass
*Various outputs: pulse, frequency, digital communication, etc
*The transmitter has the advantages of novel design, low power consumption and zero stability.
*High measurement accuracy:The accuracy of the Firm standard is required to be controlled within ±0.1%, and the range ratio is more than 2 times higher than the national standard,which ensure  the accuracy of measurement accuracy in a wide range.
*The transmitter adopts high-performance microprocessor, OLED display screen, convenient and fast parameter setting
*The transmitter adopts surface mount technology, with self-test and self-diagnosis function

Specification
Reliable Accuracy ± 0.15%F. S IP67 Output RS485 Closed Pipeline Coriolis Diesel Oil Air Gas Liquid Mass Flowmeter
Dimension
Reliable Accuracy ± 0.15%F. S IP67 Output RS485 Closed Pipeline Coriolis Diesel Oil Air Gas Liquid Mass Flowmeter
Reliable Accuracy ± 0.15%F. S IP67 Output RS485 Closed Pipeline Coriolis Diesel Oil Air Gas Liquid Mass Flowmeter
Application

Reliable Accuracy ± 0.15%F. S IP67 Output RS485 Closed Pipeline Coriolis Diesel Oil Air Gas Liquid Mass Flowmeter
Reliable Accuracy ± 0.15%F. S IP67 Output RS485 Closed Pipeline Coriolis Diesel Oil Air Gas Liquid Mass Flowmeter
Reliable Accuracy ± 0.15%F. S IP67 Output RS485 Closed Pipeline Coriolis Diesel Oil Air Gas Liquid Mass Flowmeter


 

Company Profile

Reliable Accuracy ± 0.15%F. S IP67 Output RS485 Closed Pipeline Coriolis Diesel Oil Air Gas Liquid Mass FlowmeterReliable Accuracy ± 0.15%F. S IP67 Output RS485 Closed Pipeline Coriolis Diesel Oil Air Gas Liquid Mass FlowmeterReliable Accuracy ± 0.15%F. S IP67 Output RS485 Closed Pipeline Coriolis Diesel Oil Air Gas Liquid Mass Flowmeter

Packaging & Shipping

Reliable Accuracy ± 0.15%F. S IP67 Output RS485 Closed Pipeline Coriolis Diesel Oil Air Gas Liquid Mass Flowmeter

FAQ

1. How long will you reply me?
Normally in 1 hours, no more than 12 hours.

2. How can I get the quotation?

Please provide specification and application including sensing element, pressure range, thread connection, pressure type, medium, electronic connection, shell material etc. More details, more accurate quotation and earlier response.

3. Can I get sample?

Contact with our staff online directly and they would check stock for you.

4. Can I visit your factory?

You are warmly welcomed, our factory is located at Baoji city, Shaanxi province, China. 

5. Can we use our logo on the products?

Yes, we provide OEM/ODM service. 

6. How long is your warranty period?

Warranty period from the date of acceptance of 12 months.

7. What is your terms of payment?

We could accept T/T, L/C, Western union, PayPal, credit Assurance.


 
 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier