• Wide Usage 20 Keys Interface LCD Display Diffused Silicon Ceramics Strain Sensors Debugger Calibrator
  • Wide Usage 20 Keys Interface LCD Display Diffused Silicon Ceramics Strain Sensors Debugger Calibrator
  • Wide Usage 20 Keys Interface LCD Display Diffused Silicon Ceramics Strain Sensors Debugger Calibrator
  • Wide Usage 20 Keys Interface LCD Display Diffused Silicon Ceramics Strain Sensors Debugger Calibrator
  • Wide Usage 20 Keys Interface LCD Display Diffused Silicon Ceramics Strain Sensors Debugger Calibrator
  • Wide Usage 20 Keys Interface LCD Display Diffused Silicon Ceramics Strain Sensors Debugger Calibrator

Wide Usage 20 Keys Interface LCD Display Diffused Silicon Ceramics Strain Sensors Debugger Calibrator

Type: Calibrating Device
Feature: Intelligent
Measuring Medium: Current, Vlotage
Accuracy Grade: No
Pressure range: No
IP Rating: IP65
Samples:
US$ 46/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
XYT-TS05
Certification
CE
Customized
Customized
Power Supply
DC24-28V(100mA)
Output
DC20-24V(30mA)
Display
192*64 DOT Screen Blue Screen or Green Sc
Protection Class
IP65
Temperature Range
10-45ºC
Transport Package
Carton
Specification
0.5kg
Trademark
XYT Meter
Origin
China
HS Code
9026201090
Production Capacity
50000 Piece /Years

Product Description

Product Description

Overview

Wide Usage 20 Keys Interface LCD Display Diffused Silicon Ceramics Strain Sensors Debugger Calibrator
Wide Usage 20 Keys Interface LCD Display Diffused Silicon Ceramics Strain Sensors Debugger Calibrator


TS05 debugger is a debugging tool for BS-30/31/32 series converter board. Use large LCD screen display and surface,board touch button design, using the surface plate stuck in the design, can be installed in the customer's production tooling as production equipment to use.
Strive to customers easy to use, reliable.
TS05 debugger built-in high precision ammeter and voltmeter, with RS232 communication interface, you can communicate with the computer, calibrate the board through the computer, you can also use the debugger built-in functions and panel keys to calibrate the board offline.
Reliable data verification and error detection mechanisms ensure the accuracy of user operations. With sound and display prompt function. No external ammeter is required to use this tool, only a DC 24V power supply is required. Tools are self-contained, independent work, need to configure special parameters of the transmitter, you can use the computer through the upper computer software to modify the internal parameters of the tool.
The TS05 debugger supports 4-20mA, 0-10V, 0-5V, 1-5V, 0.5-4.5V, and 5V proportional supply voltages, different access modes  can be selected through different terminal connections for board calibration.

Specification

Power supply DC24-28V(100m A)
 
Output 1 DC20-24V(30m A)
Current input 4-20m ADC Output 2 DC5V(30m A)
Voltage input 0-10VDC
 
Display 192*64 dot screen Blue screen or green screen
Ammeter display range 0.000-33.000mA Ammeter accuracy 0.05%@ room temperature
Voltmeter display range 0.000-11.000V Voltmeter accuracy 0.05%@ room temperature
Key interface Tap film 20 key Dimensions 172*94*30mm
temperature range
 
10-45ºC Display size 105*40mm
Protection class Front panel IP65 Computer interface
 

RS232
 
Transmitter communication Ehart Storage temperature -20-60ºC
Cooling method natural cooling Humidity 20%-85%RH(no condensation)

Dimension
Wide Usage 20 Keys Interface LCD Display Diffused Silicon Ceramics Strain Sensors Debugger Calibrator

Wiring diagram
Wide Usage 20 Keys Interface LCD Display Diffused Silicon Ceramics Strain Sensors Debugger Calibrator
Company Profile

Wide Usage 20 Keys Interface LCD Display Diffused Silicon Ceramics Strain Sensors Debugger CalibratorWide Usage 20 Keys Interface LCD Display Diffused Silicon Ceramics Strain Sensors Debugger CalibratorWide Usage 20 Keys Interface LCD Display Diffused Silicon Ceramics Strain Sensors Debugger Calibrator

Packaging & Shipping

Wide Usage 20 Keys Interface LCD Display Diffused Silicon Ceramics Strain Sensors Debugger Calibrator

FAQ

1. How long will you reply me?

Normally in 1 hours, no more than  12 hours.
2. How can I get the quotation?
Please provide specification and application including sensing element, pressure range, thread connection, pressure type, medium, electronic connection, shell material etc. More details, more accurate quotation and earlier response.
3. Can I get sample?
Contact with our staff online directly and they would check stock for you.
4.Can l visit your factory?
You are warmly welcomed, our factory is located at Baoji city, Shaanxi province, China.
5.Can we use our logo on the products?
Yes, we provide OEM/ODM service.
6.How long is your warranty period?
Warranty period from the date of acceptance of 12 months.
7.What is your terms of payment?
We could accept T/T, L/C, Western union, PayPal, credit Assurance.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now