Pressure Range: Atmospheric pressure
Display Type: LCD
Accuracy Grade: 0.2G
IP Rating: IP65
Certification: CE
Customized: Customized
Samples:
US$ 3800/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
QYBL-01
Power Supply
12~30V DC
Output
4-20mA DC Hart
Range
300mm - 2500mm
Nominal Diameter
DN40 or to Order
Ambient Temperature
-40 ºC to +80 ºC
Medium Temperature
-196~450
Accuracy
0.5
Display
LCD
Density
0.2≤ρ≤1.9g/cm3
Power Inlet
Two M20×1.5 (Female) or on Request
Transport Package
Wooden Box
Specification
10KG
Trademark
XYT
Origin
China
HS Code
9026201090
Production Capacity
3000/Month

Product Description

DISPLACER LEVEL TRANSMITTER
 
Summary
Our company has been developing and producing since 2006 After years of technical research and accumulation of experience, the product performance has reached the international leading level. Displacer level transmitter can be used to measure level, interface or density, output 4-20mA current signal, and have HART communication protocol. Through the compatible HART communicator, the level controller can be inquired, configured, calibrated or tested. It can also accept the information of a single measurement loop, and can transmit the information from the field to the control system.

Main technical parameter

Power supply: 12~30V DC;
Output signal: 4~20 mA DC
increase; Negative direction - the increase of level, interface, or density make output decrease.)
Measuring range: 300mm-2500mm (can also over range)
Nominal pressure: ≤42.0Mpa
Nominal diameter: DN40 or as customers' request
Ambient temperature: -40ºC to +80ºC (when ≤-30ºC, no LCD display)
Operating temperature: -70ºC to +400ºC
Measuring accuracy: 0.5%
Influence from power supply: When the voltage of the power supply varies between min. and max. ,the output change is within <±0.2%. of the full scale.
LCD display: Output current signal,process variable,process temperature,percentage range,rotation angle of torque tube.
Medium density difference: ≥0.08g/cm³
Material of torque tube: Standard configuration Inconel 600,or Monel, HasetlloyC-276
Wetted material: 304,316L or as customers' request
Flange standard: HG/T20592-2009,HG/T20615-2009 or as customers' request
Power entry: Two NPT 1/2 (female thread) or as customers' request
Explosion-proof: Explosion isolation ExdCT6, Intrinsically safe ExiaCT6
Protection grade: IP66
Alarm jumper: For the self-diagnosis to the inaccuracy failure of the process variables (for example, the electronic module failure). Configure the process variables of high and low alarms.

 
LCD Display 2000mm 4-20mA DC Hart Displacer Type Level Transmitter Displacement Level Transducers

Operating principle

Displacer level transmitter is composed of level controller and measuring chamber, displacer, torque tube and other components. The change of the measured medium level causes the buoyancy of the float to change, and the change is transmitted to the torsion tube component, which makes the torsion tube rotate one angle with the mandrel synchronously. A sensing system coupled to the torsion tube mandrel generates a voltage signal. The level controller electronic assembly measures the level (interface) signal and provides a 4 to 20 mA current output. The microcontroller measures the ambient temperature to compensate for changes in liquid density caused by changes in process temperature, and the LCD displays information such as the analog output, process variables, process temperature (RTD installation required), torsion tube rotation angle, and percentage range of the level (interface).
 
LCD Display 2000mm 4-20mA DC Hart Displacer Type Level Transmitter Displacement Level Transducers
LCD Display 2000mm 4-20mA DC Hart Displacer Type Level Transmitter Displacement Level Transducers
LCD Display 2000mm 4-20mA DC Hart Displacer Type Level Transmitter Displacement Level Transducers
 

Operation principle

DLC series smart displacer level (interface) transmitter consists of imported original DLC3000 series smart level controller and measuring chamber, measuring mechanism, displacer and torque tube, etc. The liquid level changing triggers the change of the buoyancy of displacer, then it will be transferred into the torque tube unit. This makes the torque tube and core axle rotate synchronously.
At the same time, the magnetic steel parts that fixed at the core axle of the torque tube turn rotary displacement. The Hall-effect sensor senses the magnetic field change and converts the magnetic signals into current signals. DLC3000 series smart level controller measures process variables with a controller and relative electronic circuit, supplies current output to drive LCD and support HART communication. Controller receives the electric signals that have been temperature-compensated and linearised. Meanwhile, compensates the liquid density change caused by the change of the process temperature, then supplies 4~20mA current output signals. LCD can indicate analog output, process variables, process temperature (if RTD is installed), degrees of the torque tube rotation and percent range of variable, etc.
LCD Display 2000mm 4-20mA DC Hart Displacer Type Level Transmitter Displacement Level Transducers
LCD Display 2000mm 4-20mA DC Hart Displacer Type Level Transmitter Displacement Level Transducers
 
Model       Code         Code meaning
UTZ-                 UTZ3100 Smart displacer transmitter
  1               Level measurement
  2               Interface measurement
  3               Density measurement
    A             Top-side mounted
    B             Top-bottom mounted
    C             Side-side mounted
    D             Bottom-side mounted
    E             Top mounted
    F             Side mounted
    S             Top-bottom S style mounted
      2           Nominal pressure ≤PN1.6MPa, 2.0Mpa (Class 150)
      3           Nominal pressure: PN2.5MPa
      4           Nominal pressure: PN4.0MPa
      5           Nominal pressure: PN5.0MPa (Class 300)
      6           Nominal pressure: PN6.3Mpa
      10           Nominal pressure ≤PN10MPa
      11           Nominal pressure ≤PN11MPa (Class 600)
      15           Nominal pressure ≤PN15MPa (Class 900)
      16           Nominal pressure ≤PN16MPa (Class 900)
      25           Nominal pressure ≤PN25MPa (Class 900)
      26           Nominal pressure ≤PN26MPa (Class 1500)
      42           Nominal pressure ≤PN42.0MPa (Class 2500)
        /         Intrinsically safe
          i       Explosion protection: intrinsically safe
          d       Explosion protection: explosion isolation
            T     Chamber material : carbon steel
            H     Chamber material: 304 (others as actual fill in)
            R     Chamber material: 316L (others as actual fill in)
            F     Chamber material: Stainless with PTFE coated
            X     Chamber material: Other material
              L   Medium temperature: -70ºC≤T<-30ºC
              D   Medium temperature:-30ºC≤T<+100ºC
              G   Medium temperature: +100ºC≤T≤+400ºC
                /  
  Range According to actual fill in, unit is mm.

Additional code
F Chamber with heating, flange connection DN15, PN2.5 RF
Z Chamber with heating, thread joint R1/2
  W Left mounted transmitter
mounted transmitter)
(without "W" is right

Example : UTZ-2C3/iTD/800F: smart displacer, measuring interface, side-side mounted, nominal pressure is PN6.3MPa or PN5.0MPa intrinsically safe, chamber material is carbon steel, medium temperature-30ºC≤T <
+100ºC, measuring range is 800mm, chamber with heating, flange connection with heating tracing.


LCD Display 2000mm 4-20mA DC Hart Displacer Type Level Transmitter Displacement Level TransducersLCD Display 2000mm 4-20mA DC Hart Displacer Type Level Transmitter Displacement Level TransducersLCD Display 2000mm 4-20mA DC Hart Displacer Type Level Transmitter Displacement Level TransducersLCD Display 2000mm 4-20mA DC Hart Displacer Type Level Transmitter Displacement Level Transducers
FAQ
1. How long will you reply to me?
Normally in 1 hours, no more than 12 hours.
2. How can I get the quotation?
Please provide specification and application including sensing element, pressure range, thread connection, pressure type, medium, electronic connection, shell material etc. More details, more accurate quotation and earlier response.
3. Can I get sample?
Contact with our staff online directly and they would check stock for you.
4. Can I visit your factory?
You are warmly welcomed, our factory is located at Baoji city, Shaanxi province, China.
5. Can we use our logo on the products?
Yes, we provide OEM/ODM service.
6. How long is your warranty period?
Warranty period from the date of acceptance of 12 months.
7. What is your terms of payment?
We could accept T/T, L/C, Western union, PayPal, credit Assurance.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now