Air Collector for Measuring of High Temperature 2-Wires 4-20mA Level Transmitter
QYB203 is used in various levels measuring in petroleum, chemical engineering, metallurgy, electric power, pharmacy, water supply, and environmental protection. It can display onsite and transmit to standard signals such as 4-20mA, RS485, and HART. It is been used for high-temperature conditions, or to measure oil, fuel, gasoline.
Main Features
1.High temperature 120ºC;
2. Digital pressure display;
3. Zero point, range adjustment flexible
4.Reverse polarity protection and current limiting protection
5.Anti shock, safety and explosion proof
6.Small size, beautiful appearance, cost-effective
7.High precision, high stability, high reliability.
8. Medium includes Oil
Product code |
QYB203 |
Designation |
Liquid Level Transmitter |
Measuring range |
0-10m |
Accuracy |
0.5%F.S |
Display |
No/LED/LCD |
Power Supply |
18-36VDC |
Output signal |
4-20 mA,RS485,Hart |
Threaded interface |
M20*1.5( can be customized) |
Overload
|
150% |
Medium Temperature |
0~60°C |
Operating Temperature |
-30~80ºC |
Sealed material |
Nitrile/Fluoriderubber/PTFE |
Pressure connections |
1Cr18Ni9Ti |
Sensor diaphragm |
SS316L |
Stability |
≤±0.2%FS/year |
Protective class |
IP67 |
Medium Density |
As your requirement |
QYB203 |
Level Transmitter |
|
Code |
Level type |
|
G |
gauge |
|
A |
absolute |
|
|
Code |
Input(m) |
|
|
0001 |
0-1m |
|
|
|
|
|
|
0010 |
0-10m |
|
|
|
|
|
|
|
Code |
Accuracy |
|
|
|
05 |
0.5% |
|
|
|
|
Code |
Process connections |
|
|
|
|
M3 |
M30x1.5(male) |
|
M2 |
M20x1.5(male) |
|
|
|
|
|
G2 |
G1/2(male) |
|
Nx |
Customized |
|
|
|
|
|
|
Code |
material of thread |
|
|
|
|
|
S4 |
Stainless Steel 304 |
|
|
|
|
|
|
Code |
Output Signal |
|
|
|
|
|
|
42 |
4...20mA |
|
|
|
|
|
|
48 |
RS485 |
|
|
|
|
|
|
HA |
HART |
|
|
|
|
|
|
|
Code |
Display |
|
|
|
|
|
|
|
C |
LCD |
|
|
|
|
|
|
|
E |
LED |
|
|
|
|
|
|
|
|
Code |
Explosion-proof class |
|
|
|
|
|
|
|
|
N |
Non-explosive |
|
|
|
|
|
|
|
|
E |
Explosion-proof intrinsic safety |
QYB203 |
G |
0010 |
05 |
M3 |
S4 |
42 |
C |
E |
Examples of Ordering Code: QYB201-G-0010-05-M3-S4-42-C-E |
Signal terminal is put into the electrical box, please take down the cover before connecting wire. The power is connected by the signal wire, there is no need to connect other wire.
Signal wire adopts twisted pair. We recommend the
shielded wire in the situation with serious
electromagnetic interference and please properly
connect the wire to the ground .Don't put the signal
cables into a metal tube with other power cables or
put them in the same slot, and decorate the wire far
away from strong electric facilities.
1.Range Setting
The setting supports Range Zoom without pressure
sources. IU-L represents 4mA, IU-H represents
20mA.
2. Amplification Factor: Changing Amplification
Factor could change the value shows on the screen.
After setting this value, the number shows=
Amplification Factor*/Actual measuring value
3. Null point Span
Supporting null point span without pressure
sources. After setting this value, the number
shows= Amplification Factor*/Actual measuring
value+null point span value
4. Filter factor
To prevent display value change from pressure
fluctuation. Optional value:0-5. The higher this
value is, the more stable and hysteretic the display
value is. (Filter factor would not influence current
output)
1. Please connect wire according to the drawing, there will be no signal if wrong connecting. Transmitter can work after connecting power, but it is better to preheat it for 30mins to get the stale signal.
2. This transmitter is suitable for medium which is non-corrosive to stainless steel and silicon.(Except the anti corrosive model)
3. The maximum pressure of the measured system shall not exceed the rated overload value. The transmitter's back pressure side shall not be directly connected to conductive or corrosive liquid or gas. The vents of the sealed level air-guide cable should not be blocked.
4. It is strictly forbidden to push sharp and hard things into the pressure output hole, and the flush diaphragm type transmitter can't collide with anything like hands.
5. This product is precise measuring instrument. It is strictly forbidden to break, strongly clamp, disassemble or poke the pressure hole with sharp metal instruments.
6. Non-professionals should not disassemble theinstrument circuit board or change other devices.
12 months warranty period from the receipt of products except following situations:
a. Disassemble the circuit board or part;
b. Damage the circuit due to thunderstrike or strong current;
c. Power voltage over 28V, results in damage of circuit board;
d. Water or other liquid inflow in electrical box;
e. Out of measuring range;
f. Damage of whole/part product or sensor rod manually
![Air Collector for Measuring of High Temperature 2-Wires 4-20mA Level Transmitter](//www.micstatic.com/athena/img/transparent.png)
![Air Collector for Measuring of High Temperature 2-Wires 4-20mA Level Transmitter](//www.micstatic.com/athena/img/transparent.png)
1. How long will you reply to me?
Normally in 1 hours, no more than 12 hours.
2. How can I get the quotation?
Please provide specification and application including sensing element, pressure range, thread connection, pressure type, medium, electronic connection, shell material etc. More details, more accurate quotation and earlier response.
3. Can I get sample?
Contact with our staff online directly and they would check stock for you.
4. Can I visit your factory?
You are warmly welcomed, our factory is located at Baoji city, Shaanxi province, China.
5. Can we use our logo on the products?
Yes, we provide OEM/ODM service.
6. How long is your warranty period?
Warranty period from the date of acceptance of 12 months.
7. What is your terms of payment?
We could accept T/T, L/C, Western union, PayPal, credit Assurance