Hersman Integrated Thermocouple 4-20mA RS485 Rtd Tc Thermal Resistance PT100 Small Temperature Transmitters

Product Details
Customization: Available
Type: Network Type
Measuring Medium: Temperature
Still deciding? Get samples of US$ 29/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 14001
OEM/ODM Availability
Yes
  • Hersman Integrated Thermocouple 4-20mA RS485 Rtd Tc Thermal Resistance PT100 Small Temperature Transmitters
  • Hersman Integrated Thermocouple 4-20mA RS485 Rtd Tc Thermal Resistance PT100 Small Temperature Transmitters
  • Hersman Integrated Thermocouple 4-20mA RS485 Rtd Tc Thermal Resistance PT100 Small Temperature Transmitters
  • Hersman Integrated Thermocouple 4-20mA RS485 Rtd Tc Thermal Resistance PT100 Small Temperature Transmitters
  • Hersman Integrated Thermocouple 4-20mA RS485 Rtd Tc Thermal Resistance PT100 Small Temperature Transmitters
  • Hersman Integrated Thermocouple 4-20mA RS485 Rtd Tc Thermal Resistance PT100 Small Temperature Transmitters
Find Similar Products

Basic Info.

Model NO.
QTB 100
Display Type
Non
Site Display
Site Display
Accuracy
0.5
IP Rating
IP65
Certification
ISO
Customized
Customized
Output Signal
4-20mA, 0-5/10V, RS485
Enclosure Material
Stainless Steel 304/316
Measuring Range
-200...200ºC
Power Supply
12-30VDC
Probe Diameter
6mm, 8mm, 10mm, 12mm
Probe Length
50mm, 80mm or Customized
Electrical Connections
Hirschmann, M12, Cable
Thread
M20*1.5, G1/4, NPT1/2 or Customized
Ambient Temperature
-30~70ºC
Protection
IP65
IP65
0-80%
Transport Package
Carton
Specification
0.25 KG
Trademark
XingYuTeng
Origin
China
HS Code
9026201090
Production Capacity
5000/Month

Product Description

 
Overview
QTB100 Temperature transmitter(RTD) of this series is designed for screw-fitting directly into the process, mainly in vessels and pipelines. 
These transmitters are suitable for liquid and gaseous media under moderate mechanical load and normal chemical conditions. It uses a special temperature module to make linearity correction on the temperature sensing element, outputting a standard analog/ digital signal.
It applies to temperature measurement in many different fields including petroleum, metallurgy, chemical 
industry, power station and light industry, etc.
 
Technical Data
Product code QTB100
Designation Temperature transmitter
Measuring range -200°C ... +200°C / -392°F ... 392°F
Measuring principle PT 100 RTD
Accuracy ± 0.5 % FS
Power Supply 12V ~ 30V DC( Typical: 24V DC)
Output signal 4 ... 20 mA, 0 ... 5 VDC, 0 ... 10 VDC or RS485
Electrical connections Male electrical connector M12x1, 5-pole
Pressure connections G1/4"; G1/2" ; 1/4" NPT ; 1/2" NPT
Ambient temperature  -25°C ... +80°C
Storage Temperature  -40ºC~ 120ºC
Enclosure Materia Stainless steel 304/316
Protective class IP65
Hersman Integrated Thermocouple 4-20mA RS485 Rtd Tc Thermal Resistance PT100 Small Temperature TransmittersHersman Integrated Thermocouple 4-20mA RS485 Rtd Tc Thermal Resistance PT100 Small Temperature TransmittersHersman Integrated Thermocouple 4-20mA RS485 Rtd Tc Thermal Resistance PT100 Small Temperature TransmittersHersman Integrated Thermocouple 4-20mA RS485 Rtd Tc Thermal Resistance PT100 Small Temperature TransmittersHersman Integrated Thermocouple 4-20mA RS485 Rtd Tc Thermal Resistance PT100 Small Temperature TransmittersHersman Integrated Thermocouple 4-20mA RS485 Rtd Tc Thermal Resistance PT100 Small Temperature Transmitters
Model selection
QTB100 Temperature Transmitter
  Range [X ~ YºC ] X,Y is the temperature upper limit and lower limit, unit ºC .(full range -200ºC~ 200ºC )
R1  0-100ºC
R2  -50~100ºC
R3  -50~200ºC
R4  -200~100ºC
R5  -200~200ºC
R6 Customized range
  Code  Output Signal
42 4...20mA
48 RS485
10 0...10Vdc
5 0...5Vdc
  Code Probe diameter Unit: mm
6 φ6
8 φ8
12 φ12
16 φ16
  Code Electrical Connection
H Angular connector DIN43650
M Circular connector M12 x 1 (5-pin)
Z Cable outlet with PVC-cable,length=1.5m
  Code Pressure connections
M2 M20x1.5(male) N2 NPT 1/2(male)
G4 G1/4(male) N4 NPT 1/4(male)
G2 G1/2(male) Nx Customized
QTB100 R1 42 6 H M2 Examples of Ordering Code: QTB100-R1-42-6-H-M2
Hersman Integrated Thermocouple 4-20mA RS485 Rtd Tc Thermal Resistance PT100 Small Temperature TransmittersHersman Integrated Thermocouple 4-20mA RS485 Rtd Tc Thermal Resistance PT100 Small Temperature TransmittersHersman Integrated Thermocouple 4-20mA RS485 Rtd Tc Thermal Resistance PT100 Small Temperature TransmittersHersman Integrated Thermocouple 4-20mA RS485 Rtd Tc Thermal Resistance PT100 Small Temperature Transmitters
FAQ
1. How long will you reply to me?
We will reply to you as soon as possible. Normally in 1 hours, no more than 12 hours.
2. How can I get the quotation?
Please provide specification and application including sensing element, pressure range, thread connection, pressure type, medium, electronic connection, shell material etc. More details, more accurate quotation and earlier response.
3. Can I get sample?
Contact with our staff online directly and they would check stock for you.
4. Can I visit your factory?
You are warmly welcomed, our factory is located at Baoji city, Shaanxi province, China.
5. Can we use our logo on the products?
Yes, we provide OEM/ODM service.
6. How long is your warranty period?
Warranty period from the date of acceptance of 12 months.
7. What is your terms of payment?
We could accept T/T, L/C, Western union, PayPal, credit Assurance.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier