Oil Water Liquid LCD Display Aluminum Industrial Digital Turbine Flow Transmitter
Overview Electronic Aluminum Turbine Pulser Digital Diesel Fuel Flow Meter with LCD Display With high accuracy, durable life, small volume, Electronic Aluminum Turbine Pulser Digital Diesel Fuel Flow Meter Series are mainly used to transfer light oil such as diesel, gasoline. Its module design can be used with output module, sensor and long-distance transfers. Other Material like Plastic or Stainless Steel are also available.
The model designed can be used in conjunction with output module, sensor and remote transmitter. Good repeatability and strong stability, unique LCD (LCD)count, you can reset the 5 bit (9999.9) single oil volume, a cumulative total of 6 bits are not cleared. The accuracy ofthe positive and the negative is less than or equal to 1%the repeatability error of less than 2% units of measurement for (/L, /GAL /QTS a gallon, quart, pint (PTS)switch freely is the rise in domestic basic, easy to use), two keys (CALIBRATE DISPLAY) with the use of simple and easy to operate!
Model Number
Item1
Item2
Inlet Size
1'
1.5'
Flow Rate
20-150 lpm
40-350 lpm
Body Material
Aluminum
Aluminum
Application Medium
Diesel, light oil
Diesel, light oil
Unit Count
5 digits
5 digits
Total Count
5 digits Accumulationx100 999,990
Max.Working Pressure
290pa(20 bar)
290pa(20 bar)
Package
20 pcs/carton
20 pcs/carton
Carton Dimension
45x43x20 cm
45x43x20 cm
G.W/N.W
12kgs/11kgs
15kgs/14kgs
SET OF MEASUREMENT UNIT Under the state of standby or current charging display, press the button of CAL and RESET at the same time for 5 seconds. Enter the setting of unit conversion and press the RESET button, choose the measurement unit in turn according to the order of LTR→GAL→PT→QT→LTR, meanwhile the accumulated charging quantity will be displayed based on the conversion of the current measurement unit conversion. Then press the CAL button for 3 seconds to quit the unit conversion setting.
Error Coefficient Calibration Under the state of standby or current charging display, press the button of CAL for 3 seconds, entering the state of error coefficient calibration. Meanwhile when the first digital blinking displays, press the MENU button, then numeric shift (blinking digital displacement), press the RESET button, modify the current blinking figure, from 0 to 9 in turn, then back to 0. The oil pump capacity is less when the digital is increased; vice versa. Press the button CAL for 3 seconds to quit the error coefficient calibration. Back to the state of current charging quantity, and display it as reset. After the error coefficient calibration, demarcate it when there is new measuring pulse input. The range of the error coefficient calibration is from 0.1000 to 9.9999. Press the button of CAL and RESET at the same time to check the coefficient and total accumulated figure.
EXAMPLE OF Error Coefficient Adjustment When the original figure is 1.000, it will display as 100 L oil, the actual oil pump capacity is also 100 L. In case the user wants to reduce 2 L oil, then press the button of CAL for 3 seconds, adjust it to 1.020 according to the Error coefficient Calibration. Then the oil pump capacity will be 98 L. For 96 L, adjust it to 1.040; visa versa. Battery Low Prompt When the voltage of battery is between 2.2 v to 2.4 v, it will display as LBAT, to remind the user to replace the battery.
Maintenance and Preservation This flow meter needs the battery with life span of at least 9,000 hours (1 year) as the power supply. The short battery life will lead to the battery leakage during working and result in the damage of the flow meter. The standby life of this flow meter is designed as 2 years. Battery replacement every one year is recommended. In case the LCD display becomes dim or the LBAT occurs, it is time to replace the battery. We recommend the users to check the Battery electrode to clear the rusting in case. Take out the battery if the flow meter is not used for a long time.
Parameters Company Profile
FAQ
1. How long will you reply to me?
Normally in 1 hours, no more than 12 hours. 2. How can I get the quotation?
Please provide specification and application including sensing element, pressure range, thread connection, pressure type, medium, electronic connection, shell material etc. More details, more accurate quotation and earlier response. 3. Can I get sample?
Contact with our staff online directly and they would check stock for you. 4. Can I visit your factory?
You are warmly welcomed, our factory is located at Baoji city, Shaanxi province, China. 5. Can we use our logo on the products?
Yes, we provide OEM/ODM service. 6. How long is your warranty period?
Warranty period from the date of acceptance of 12 months. 7. What is your terms of payment?
We could accept T/T, L/C, Western union, PayPal, credit Assurance.