Overview
Ultrasonic level meter (for material and liquid level measurement) is a non-contact highly reliable and cost-effective material level measuring instrument which is easily installed and maintained. It can meet most of the material level measurement requirements without touching the medium. It is a new generation ultrasonic level meter with fully independent property rights developed by the company via years of hard work.
Specification
Function |
Integrated Type |
Separate Type |
Measuring range |
5m, 10m, 15m, 20m, 30m, 40m, 50m, 60m |
5m, 10m, 15m, 20m, 30m, 40m, 50m, 60m, 70m |
Measurement accuracy |
0.5%-1.0% |
0.5%-1.0% |
Resolution ratio |
3mm or 0.1% (whichever is greater) |
3mm or 0.1% (whichever is greater) |
Display |
English LCD |
English LCD |
Analog output |
4-line system, 4~20mA/ 510Ω load 2-line system, 4~20mA/ 250Ω load |
4~20mA/ 510Ω load |
Relay output |
2 groups (i.e. AC 250V/ 8A or DC 30V/ 5A) optional, state programmable |
2 groups for single channel and 4 groups for double channels (optional) AC 250V/ 8A or DC 30V/ 5A, state programmable |
Power supply |
Standard configuration: 24VDC Optional: 220V AC+15% 50Hz |
Standard configuration: 220V AC+15% 50Hz Optional: 24VDC 120mA Customized: 12VDC or battery powered |
Ambient temperature |
Display instrument: -20~+60ºC Probe: -20~+80ºC |
Display instrument: -20~+60ºC Probe: -20~+80ºC |
Communication |
485, 232 communication (optional) (manufacturer agreement) |
485, 232 communication (optional) (manufacturer agreement) |
IP grade |
Display instrument: IP65, probe: IP68 |
Display instrument: IP65, probe: IP68 |
Probe cable |
None |
100m available, standard configuration: 10m |
Probe installation |
Select type based on measuring range and probe |
Select type based on measuring range and probe |
Dimensions
(2)Enhanced integrated-type ultrasonic level meter:
Details
Installation
Understand terminology
Measuring range: the meaning of measuring range is very important for meter type selection. Please refer to the diagrams below.
Emitting angle and false echo
Ultrasonic wave beam is gathered by the probe. The emitting of impulse wave beam is like the light beam of flashlight. The further it is from the probe, the greater the diffusion area is.
Any objects within the range of emitting angle, such as pipe, support, weld joint, reinforcing rib, mixing propeller and hanging object, will lead to strong false echo, specially the objects within the range of emitting angle which are near the probe.
For example, the false echo caused by the pipe at 6m from the probe is 9 times stronger than that caused by the same pipe at 18m from the probe.
*Try every effort to make the sensor axis perpendicular to the medium surface and avoid any other object within the range of emitting angle, such as pipe and support.
Application
River level monitoring Tank level monitoring Sewage pool level monitoring
Company Profile
Packaging & Shipping
FAQ
1. How long will you reply me?
Normally in 1 hours, no more than 12 hours.
2. How can I get the quotation?
Please provide specification and application including sensing element, pressure range, thread connection, pressure type, medium, electronic connection, shell material etc. More details, more accurate quotation and earlier response.
3. Can I get sample?
Contact with our staff online directly and they would check stock for you.
4. Can I visit your factory?
You are warmly welcomed, our factory is located at Baoji city, Shaanxi province, China.
5. Can we use our logo on the products?
Yes, we provide OEM/ODM service.
6. How long is your warranty period?
Warranty period from the date of acceptance of 12 months.
7. What is your terms of payment?
We could accept T/T, L/C, Western union, PayPal, credit Assurance.